The silicone will spread and adhere creating a seal.
Roof anchor installation instructions.
If two roof anchors are installed onto a roof structure each anchor location must be independently capable of supporting 5 000 lbs.
You may need to cut panels to fit angles using a circular saw with a metal saw blade.
Slopes 4 12 and more a lay out anchordeck synthetic roofing underlayment horizontally parallel to the eave with the printed side up.
During installation and assembly of the anchor device ensure that the installer is not less that 2 m from any edge or opening.
Roof anchors can be as simple as a d ring connection or as complex as a complete lifeline system.
Install the panel so that the short lip overlaps the large lip.
Anchor points are usually installed on the roof and are used to connect lanyards lifelines and other forms of tie off which prevent a worker from falling.
Metal roofing is also available in the form of shingles.
Always install the anchor device so no part of the device is less 2 5 m from the edge of the roof or opening.
Minimum tensile load a qualified person must confirm that the support structure maintains a safety factor of two as per osha 1926 502.
2 way roof anchor installation instructions this product is part of a personal fall arrest system.
The roof material must be capable of supporting a minimum tensile load of 5 000 lbs.
B install anchordeck synthetic roofing underlayment without wrinkles.
The users must read and abide by the manufacturer s instructions for each element of the system.
Each of our roofing technicians has received extensive training to properly install roof anchors within the rules and regulations of osha.
Each roof anchor installation must be independently capable of sustaining this load.
More than one roof anchor is installed to a roof structure the strengths given in a or b above must be met at each roof anchors installation point independently.
Do not stretch during installation.
Installation guidelines for different slopes categories are listed below.
Applied in any direction permitted by the restraint system when in use.
3 0 operation and use.
In general roof anchors should be installed on roofs or structures that are made of wood and sheathing.
If the material is not able to support 5 000 lbs.
Screw the new panel in place as described.
Installation of this roof anchor must be certified by a qualified person or engineering service.
Not for use as an abseiling point.
Continue adding panels until the roof is covered.
Roof anchors installed for restraint applications must be attached to a roof member capable of sustaining a static load of at least 3 000 lbs.